存储 频道

征文:TSM不能取出放入磁带问题解决

问题的分析与解决

  驱动器:

Library Name: 3582LIB
Drive Name: DRIVE01
Device Type: LTO
On-Line: Yes
Read Formats: ULTRIUM3C,ULTRIUM3,ULTRIUM2C,ULTRIUM2,ULTRIUMC,ULTRIUM
Write Formats: ULTRIUM3C,ULTRIUM3,ULTRIUM2C,ULTRIUM2
Element: 257
Drive State: EMPTY
Volume Name:
Allocated to:
WWN:
Serial Number: 1210088095
Last Update by (administrator): ADMIN
Last Update Date/Time: 12/04/07 11:03:59
Cleaning Frequency (Gigabytes/ASNEEDED/NONE): NONE
Library Name: 3582LIB
Drive Name: DRIVE02
Device Type: LTO
On-Line: Polling Since 12/04/07 14:38:12
Read Formats: ULTRIUM3C,ULTRIUM3,ULTRIUM2C,ULTRIUM2,ULTRIUMC,ULTRIUM
Write Formats: ULTRIUM3C,ULTRIUM3,ULTRIUM2C,ULTRIUM2
Element: 256
Drive State: RESERVED
Volume Name:
Allocated to: TSM
WWN:
Serial Number: 1210175967
Last Update by (administrator): ADMIN
Last Update Date/Time: 12/04/07 10:24:54
Cleaning Frequency (Gigabytes/ASNEEDED/NONE): NONE


Source Name: TSM
Source Type: SERVER
Destination Name: 3582LIB
Destination Type: LIBRARY
Library:
Node Name:
Device: /dev/smc0
External Manager:
LUN:
Initiator: 0
Directory:
On-Line: Yes
Last Update by (administrator): ADMIN
Last Update Date/Time: 04/19/07 12:34:06
Source Name: TSM
Source Type: SERVER
Destination Name: DRIVE01
Destination Type: DRIVE
Library: 3582LIB
Node Name:
Device: /dev/rmt1
External Manager:
LUN:
Initiator: 0
Directory:
On-Line: No
Last Update by (administrator): SERVER_CONSOLE
Last Update Date/Time: 12/04/07 14:04:26
Source Name: TSM
Source Type: SERVER
Destination Name: DRIVE02
Destination Type: DRIVE
Library: 3582LIB
Node Name:
Device: /dev/rmt2
External Manager:
LUN:
Initiator: 0
Directory:
On-Line: Yes
Last Update by (administrator): ADMIN
Last Update Date/Time: 03/23/07 11:06:33

在server(AIX 5.3系统)看到的错误是:
IDENTIFIER TIMESTAMP T C RESOURCE_NAME DESCRIPTION
825849BF 1204084607 T H fcs2 ADAPTER ERROR
3074FEB7 1204084607 T H fscsi2 ADAPTER ERROR

  问题分析与解决:

  最后分析很有可能是硬件问题。然后检查了光纤接口,发现有一路亮黄灯。后来发现是接口坏了,换了一个新接口。重新扫描一下,重启了TSM。问题解决了。

0